New Air Leakage Finder 225 (ALF225) Launches

Designed to test larger ductwork than the Air Leakage Finder 150 (ALF150) whilst maintaining the simple control system and a portable design, the Air Leakage Finder 225 (ALF225) has increased fan power building up the static pressure fast, allowing for longer ductwork sections to be tested.

Like the ALF150 the new ALF225 utilises three easy to change conical inlet nozzles designed to ISO5801 and allows the machine to cover the range for 1l/s to 225l/s, these precision machined nozzles, combined with a recently enhanced control POD gives an accuracy of +/-2.5% of reading.

This all-in-one instrument provides a closed-loop controlled leakage test, and the configurable test parameters include duct size, test pressure, test duration & test class. Once it is configured appropriately, the ALF225 control pod will calculate the maximum allowable leakage for the ductwork system and then run the test – first pressurising or depressurising the ductwork to the test pressure set, then monitoring the leakage rate, and finally indicating whether the ductwork installation has failed or passed the test.

The new ALF225 will sit above the ALF150.  The model numbers directly relate to the maximum flowrate in l/s at the industry standard +/-2500Pa, so the new ALF225 can deliver up to 225l/s at 2500Pa and can test to standards DW/143/144/154, ISO EN1507/12237/12599 or SMACANA. As well as a free test mode for custom applications like chilled beam/discharge profiling.

Ductwork leakage measurements are used to diagnose and demonstrate leakage problems, estimate efficiency losses from duct leakage, and certify the quality of the duct system. When the air leakage testing is carried out, data can be captured and subsequently saved in a .txt format via SD card or output via mini-USB cable. 

Many are unaware of the advantages made when diagnosed maintenance is carried out following a duct leakage performance test. These include considerable savings in future energy bills as well as improved levels of occupant comfort.

On-site testing for ductwork leakage is only required sporadically, so the unit’s simple operation removes the need to relearn technical skills each time. The closed loop PID control feature allows automatic fan control and pressure correction as the duct integrity is improved during a test. The range of ALF duct leakage testers are compact, lightweight and a totally self-contained all in one unit that can be manoeuvred, connected, and operated by a single engineer. The intuitive single interface Control Pod reports duct static pressure, leakage flow and controls the fan. Removing the complexity that might be associated with operating a duct work leakage tester and other forms of testing equipment. Our ALF range allows the engineer to be provided with everything needed to test ductwork systems for leakage under both positive and negative pressure.

Find out more about Sensing Precision Limited on their member profile page here

Member-created content 1 year ago | From members

More News